LibreNMS 自訂CPU溫度監控警報

自訂OID

確認已經建立OID,名稱統一為CPU溫度,後續只要自訂CPU 監控OID都能統一套用

image.png

建立警報規則

選擇Create rule from collection,選擇CustomOID over warning limit

image.png

Add rule放在上面,讓descr匹配CPU溫度

image.png

建立警報範本

image.png

{{ $alert->title }}
設備名稱: {{ $alert->display }} 
@if (!empty($alert->uptime_short))
運行時間: {{ $alert->uptime_short }}
@endif
@if ($alert->state == 0)
持續時間: {{ $alert->elapsed }}
恢復時間: {{ $alert->timestamp }}
@else
告警時間: {{ $alert->timestamp }}
@if ($alert->faults)
@foreach ($alert->faults as $key => $value)
超過告警值: {{ $value['customoid_limit_warn'] }} °C
{{ $value['customoid_descr'] }} 溫度: {{ $value['customoid_current'] }} °C
@endforeach
@endif
@endif

此為通用範例自行修改

image.png

image.png


Revision #4
Created 6 November 2026 07:18:31 by Jason
Updated 8 November 2026 04:04:54 by Jason